您好,欢迎来到半岛官网网站 网站!

服务热线

当前位置: 首页- 新闻中心> 业内资讯
常见问题
新闻中心

MNS2.0型低压抽出式开关柜使用特点

发布时间:2023-08-27来源://www.aqfitlab.com/浏览量:

上通风门、电缆室门和后门,转动部分由暗铰链改为明铰链,这使得门转动平稳,转动角度更大,同时也比以前要美观,整体效果更加协调。
The upper ventilation door, cable room door, and rear door have been changed from concealed hinges to exposed hinges in their rotating parts, which makes the door rotate smoothly, with a larger angle of rotation, and is also more aesthetically pleasing than before, resulting in a more coordinated overall effect.
改进前,一次转接件与塑料功能件直接相连。假如发生特殊故障,导致一次转件烧毁,这样会给现场的维修带来较大的困难,更换时间较长。而改进后,由于一次转件改为独立安装维修方便,减少了停电时间,经济效果显著。
Before the improvement, the primary adapter was directly connected to the plastic functional component. If a special malfunction occurs, resulting in the burning of a rotating part, it will bring greater difficulties to on-site maintenance and a longer replacement time. After the improvement, due to the convenience of independent installation and maintenance instead of one-time parts transfer, the power outage time was reduced, and the economic effect was significant.
柜的一次电缆出线方便更加灵活。相比以前,除了保留原有的侧出和后出的方案,更增加了同时侧出和后出的混合方案,极大的方便了用户。
The primary cable outlet of the cabinet is more convenient and flexible. Compared to before, in addition to retaining the original side out and rear out schemes, a hybrid scheme of simultaneous side out and rear out has been added, greatly facilitating users.
16E和24E单元抽屉内的一次电联的规格可以根据回路的实际电流大小选择电缆,这有利于用户现场的维修和更改。
The specifications of the primary electrical connection in the drawers of the 16E and 24E units can be selected based on the actual current size of the circuit, which is beneficial for on-site maintenance and modification by users.
MNS低压抽屉柜
改进后,后出线方案的后门结构与以前相比,对中立柱进行了重新优化,从而增加了出线电缆的空间,便于用户维修。
After improvement, the rear door structure of the rear outlet scheme has been re optimized on the center pillar compared to before, thereby increasing the space for outlet cables and facilitating user maintenance.
改进后,后出线方案的二次接插件由侧面位置改到后隔板位置。这样,不但减少了二次电缆到端子的距离,而且避免了因现场柜子并柜后无法维修的问题。(600mm宽后出线方案容易产生)。
After improvement, the secondary connector of the rear outlet scheme has been changed from the side position to the rear partition position. This not only reduces the distance from the secondary cable to the terminal, but also avoids the problem of being unable to repair after on-site cabinet merging. The 600mm wide rear outlet scheme is easy to generate.
可翻门式顶盖,安装方便,省力省时。
The foldable door top cover is easy to install, labor-saving, and time-saving.
使用条件
Usage conditions
周围空气温度不高于+40℃,不低于-5℃,而且24h内其平均温度不高于+35℃。
The ambient air temperature shall not be higher than+40 ℃, not lower than -5 ℃, and its average temperature within 24 hours shall not be higher than+35 ℃.
周围空气相对于湿度在高温度为+40℃时不超过50%,在较低温度时有较大的相对湿度,如+20℃时为90%,但考虑到由于温度的变化有可能会偶然产生适度的凝露。
The relative humidity of the surrounding air does not exceed 50% at the highest temperature of+40 ℃, and there is a significant relative humidity at lower temperatures, such as 90% at+20 ℃. However, considering that moderate condensation may occur occasionally due to temperature changes.
户内使用时,使用地点的海拔高度不超过2000m。
When used indoors, the altitude of the location of use shall not exceed 2000m.
应安装在无剧烈震动和冲击,以及不使电器元件受到腐蚀的场所。
It should be installed in a place without severe vibration and impact, as well as in a place that does not corrode electrical components.
有了 MNS低压抽屉柜上面的小总结,希望对广大客户有所帮助,如果有什么不理解的或者寻求帮助的请点击我们的网站: //www.aqfitlab.com或者来电咨询,我们会尽全力为您解决
With the summary on the MNS low-voltage drawer cabinet, I hope it can be helpful to our customers. If you have any questions or need help, please click on our website: //www.aqfitlab.com Or call for consultation, and we will do our best to solve it for you
首页首页 产品产品 电话电话 置顶置顶
Baidu
map