室外机箱机柜功能要求有哪些?

发布时间:2022-03-21来源://www.aqfitlab.com/浏览量:

近几年不锈钢机型机柜在机构设计上也有很大的,采用不锈钢门轴,双源端子箱把手,用箱门内部装有限位和防反弹机构;引线敲落孔改进为"工"字型可拆卸结构,方便了电缆的引入;箱体采用不锈钢材料制作,强度好、硬度高、表面美观、密封性好、性强、寿命长、易维护。
In recent years, there are also great differences in the mechanism design of stainless steel type cabinet. Stainless steel door shaft and dual source terminal box handle are adopted, and the box door is equipped with limit and anti rebound mechanism; The lead knock-out hole is improved to an "I" shaped detachable structure to facilitate the introduction of cables; The box is made of stainless steel, with good strength, high hardness, beautiful surface, good sealing, strong, long service life and easy maintenance.
室外机箱机柜功能要求
Functional requirements for outdoor cabinet
1、室外电信设备机柜内需含有安装电源设备、通信设备、配线设备(MDF、ODF)、温控设备、蓄电池、监控单元及其它备附件的功能区组成。各部分的功能具体要求如下:
1. The outdoor telecommunication equipment cabinet shall be composed of functional areas for installing power supply equipment, communication equipment, wiring equipment (MDF, ODF), temperature control equipment, storage battery, monitoring unit and other spare accessories. The specific functional requirements of each part are as follows:
半岛电竞中国总部地址电话
2、电源设备安装区:满足设备正常运行的交、直流供电设备安装的空间要求。
2. Power supply equipment installation area: meet the space requirements for the installation of AC and DC power supply equipment for normal operation of the equipment.
3、通信设备安装区:满足电信设备安装的空间要求。
3. Installation space of telecommunication equipment: meet the requirements of telecommunication equipment installation area.
4、配线区:满足通信设备所需配置的MDF和DDF配线模块安装的空间。
4. Distribution area: the space for the installation of MDF and DDF distribution modules required by communication equipment.
5、温控设备区:满足设备正常运行的热交换系统或空调设备的安装空间要求。
5. Temperature control equipment area: meet the installation space requirements of heat exchange system or air conditioning equipment for normal operation of equipment.
6、电池安装区:满足通信设备正常运行所配置的蓄电池存放空间要求。
6. Battery installation area: meet the storage space requirements of the battery configured for the normal operation of communication equipment.
7、监控单元:具有处理4.5节要求的各种的监控、告警能力,并具有标准的传送接口。
7. Monitoring unit: it has the ability to handle various monitoring and alarm required in section 4.5, and has standard transmission interface.
8、其它备附件:在机柜正面应有电信LOGO的标识,标识的大样如图1所示、标识的位置、颜色及大小可根据用户要求确定;在机柜的门靠上合适位置配置挂牌(方便各使用单位对机柜编号进行标识),以及其它附件等。
8. Other spare accessories: the front of the cabinet shall be marked with telecom logo. The detail of the logo is shown in Figure 1. The location, color and size of the logo can be determined according to the user's requirements; A tag (convenient for each user to identify the cabinet number) and other accessories shall be configured at a suitable position near the door of the cabinet.